Image not loaded

VERTICAL HIGH PRESSURE STEAM STERILIZER – TRIPLE WALLED “MAC” MSW-102

This is a small description

FEATURES

  • “MAC” Vertical Autoclaves are most ideal for all applications requiring, routine total destruction of all living micro-organisms
  • An Ideal tool for Laboratories, hospitals, nursing homes, R & D labs etc.
  • Heaters cover stand and carrier/bucket are made of Stainless Steel.
  • Specially designed system for dry sterilization processes, the system is a triple walled unit with inner chamber, jacked and outer wall made of Stainless Steel.
  • Lid made of Stainless Steel is closed through a RADIAL LOCKING ARRANGEMENT.
  • The chamber is leak proof and all joints are duly argon arc welded.
  • Mounted on mild steel support legs.
  • The system is supplied without basket and without dressing drum, however the same are available at extra cost.
  • Lid is fitted with Pressure Gauge, Spring Loaded Safety Valve, Manual Exhaust Valve, Vacuum Breaker-cum-Purge Valve as a safety device and water level indicator.
  • Drain Valve facilitates easy cleaning of the chamber.
  • All internal joints are argon arc welded, ground and polished to give crevice free internals.
  • Operating range from 15 to 20 psi pressure (adjustable).
  • Industrial grade energy efficient heaters reduce power bills drastically.
  • To work on 220/230Volts, 50/60 Hz AC supply.
Technical Specifications & Ordering Informations
INPUT VOLTAGE#VSS-40(LED)#VSS-78(LED)
Inner Dimensions (Dia x Height)300×500mm400×600mm
Capacity40 ltrs78 ltrs
Heater Load3.0 KW4.0 KW
Sterilizing Pressure1.2 kgf /cm² (15 psi) at 121ºC
Pressure Gauge0-2.1 kgf /cm² (30 psi)
Operating PressureFrom 15psi to 20 psi (Adjustable)
GasketMade of Jointless Silicon Rubber
Controller (PLC Based)µProcessor Based Fully Automatic Fuzzy Logic Control System
Display16×2 line Alphanumeric Digital LCD with backlet display with Set Value (SV) and Process Value (PV)
Timer (Auto Time Control) & BuzzerFitted with AUTOMATIC DIGITAL MINUTE TIMER which starts automatically when set/desired value of temperature is achieved. When the set time period is over the heaters get switched off automatically with alarm for cycle end.
Display16×2 line Alphanumeric Digital LCD with backlet display with Set Value (SV) and Process Value (PV)
MOC (Pressure Vessel)Stainless Steel (SS-304)
MOC (External Wall)Stainless Steel (SS-304)
MOC (Top Lid)Thick machined Stainless Steel plate
Power Supply220/230V AC, 50/60Hz

Option

  • G-LOG – Fully automatic digital (FAD) with real time data logger with CENTRONIC PRINTER PORT (DOT MATRIX) and USB Port for taking data (Paperless Data Recording) and Saving ON PC. (DOT Matrix Printer to customer scope)
  • P-LOG – Fully automatic digital (FAD) with real time data logger with CENTRONIC PRINTER PORT (DOT MATRIX) and RS-485 PC communication port with 21 CFR compliant software and data cable for logging data directly to your PC. (DOT Matrix Printer and PC to customer scope)
  • Validation documentation (Mapping) with (3+1) point temperature scanning for one cycle each on empty and loaded conditions (to cost extra)
  • Drain/Exhaust cooling through a cooling coil condenser for condensate collection.
  • TFT Touch Screen Display Controller in lieu of LCD display.
  • Vacuum Pulsing thru a vacuum pump.
  • Spare Silicon Gasket to cost extra.
  • Spare Heater to cost extra.