FUME HOOD (MODULAR) “MAC” MSW-16701
Modular fully loaded chemical fumes extraction hoods after excellent performance and high suction power. Excellent chemical resistance & international quality electrical & gas connection utilities.
Application
General Chemical Fume Section Hood
Design Basis
Comply to ASHRAE-110 Standards for face velocity
Certifications
CE, ISO 13485:2016, ISO 9001:2015, ISO 14001:2015, ISO 45001:2018, ISO 12100-2010, EN 60601-1 2006, IP 20, IP 21, IEC 61010-1, IEC 60601-1, BS EN 12469:2000, U.S. FDA, RoHS & WHO-GMP CERTIFIED
Fume Hood Structure
Aerodynamic Floor Mounted.
Air Flow Type
Low Constant Volume Exhaust Type
Noise Level (At Main Body)
<60db sound levels (Blower to be mounted on a remote mounting kit)
Construction
Double Skinned
Structure Outer Skin (MOC)
Super Structure Constructed out of CRC Powder Coated.
Work Top
Traditionally our work tops are made of thick DISHED CORED GRANITE even thicker at MARINE EDGES, preventing spillages and accidental damages. Chemical resistance splash & spilledge proof having skirting fromal the side, top revent chemical spillage.
Cup Sink
Made of PP/Porcelain Sink, to collect chemical waste on Work top.
Inner chamber vertical liner
Chemical & Heat Resistance, Fire retardent, smooth finish, easily cleanable, panel made out of PRL integral work (6 mm thick).
Epoxy Powder Coating
Powder coated with highly chemical resistant epoxy colors.
Baffle
Unique designed removeable back baffle captures and removes or slides fumes instantly at much faster speed.
Utility Valves
Our Valves have fine control over utilities as per international standards and with stands 200PSI pressure & brass fitting for gas connections. 1 No. for Water, 1 No. for Compressed Air, 1 No. for Nitrogen, 1 No. for Vacuum.
Suction
3-point suction system (for light, normal and heavy fumes) with baffle and fined horizontal slots aids in distributing the flow of air.
Airfoil
Aerodynamic Design, Horizontal fixed air foil mounted on worktop, provides spill retention and safe ventilation of fumes generated with ergonomic design.
Lighting
Fluroscent light (40 Watt x 2Nos.) with vapour-Proof for proper illumination. Intensity approx 400 luxon worktop.
Electric Utility
2 Nos. 15 Amp. Sockets & Switches. 1 No. MCB Switch for the Blower.
Exhaust Port
A Unique design pattern of Exhaust Port ensures that the fumes will get exhausted smoothly w/o any turbulance at exhaust port, even it takes care of low noise as well.
Exhaust Collar
Craftly tapered and flanged exhaust collar reduces airflow turbulances induces high static pressures reduces noise levels to minimal and also increases face velocity exhaust.
Centrifugal Blower
SISW type, Chemical & heat resistance heavy duty epoxy coated blower with aerodynamically balanced Impeller with Drainplug. Consisting of continuous rating motor and chemical resistant. Blower will give face velocity of 80 to 100 Feet/minute (FPM) and a high static pressure at defined sash position. It satisfies all national and international safety velocity norms.
Maximum Air Exhaust Air Volume
Minimum face velocity of 0.5m/s or 100 fpm at defined sash position
Motor
Heavy Duty Motor, 3 Phase TEFC, IP55, class F continuous rated.
Front Top Panel
Easily openable panel, to access Damper & to light fixture, for maintenance purpose.
Sash (Shutter)
Vertical rising sash counter –balanced with pulley & counter weight system. Toughned float glass (4mm thick). Clear open able height of 700mm.
Service Panels
All the front and side service panels are pre-fabricated and demountable for on-site errections and commissioning, provides easy access to service lines, utility, electrical utilities for maintenance and user conversance.
Levelling Feet
Specially designed levelling feet for balancing of cabinets and work tables as well as for height corrections and alignment vis-a-vis any floor abnormalities.
Base Cabinet
Base cabinet is capable of receiving load of Fume Hood on its top with following features : * Complete rigid steel structure to support Fume Hood. * Attractive Color combination on Epoxy powder coated Structure. * Double skin shutters / Doors. * One removable horizontal partition to store the chemicals with one shelf. * Locking system with self closing hinge. * Shutters mounted to the modules are detachable concealed hinges self closing on return. Self Closing Hinges : Three dimensionally adjustable and crome plated self closing hinges have a 900 opening. All the shutters are detachable and easy to mount. Adjustable Shelves : Modular and adjustable shelf height for flexibility to store chemicals, glasswares, accessories etc. Double-Skin Construction : All shutters and drawer fronts are double skinned and are sandwitched and stuffed for extra rigidity and strength.
LATTICE/SCAFFOLDING (OPTION)
Scaffold/Grid, to hold the apparatus. It covers the entire length of Fume Hood installed at a distance of approx. 150mm from the from backside of Fume Hood.
Ducting (OPTION)
Rigid ducting of PVC with bends, dampers, transitions and clamps upto blower. All joints are curved in order to avoid any back tracking of fumes and a smooth flow to exhaust fumes.
Fire Extinguisher
Portable can (1 No.)
NOTE CUSTOMER SCOPE
All types of Civil work, Plumbing, Block Foundation, Lab painting, Utility Connection & Electric Connection for & up to the Fume Hood and mounting of remote kit will be in Customer scope. Clear False Ceiling Height for Fume Hood and Exhaust Ducting, should be provided. Provision for Blower Foundation or Platform will be under your scope.
| Technical Specifications & Ordering Informations | ||||
| Model | #STERIMAX-3 (DX) | #STERIMAX-4 (DX) | #STERIMAX-5 (DX) | #STERIMAX-6 (DX) |
|---|---|---|---|---|
| External Dimensions (WXDXH) mm | 1200x850x2300 | 1500x850x2300 | 1800x850x2300 | 2100x850x2300 |
| Internal Dimensions (WXDXH) (mm) | 950x750x1200 | 1250x750x1200 | 1550x750x1200 | 1850x750x1200 |
OPTIONS
- PVC Ducting per running feet.
- Panel Mounted Remote Controlled Utility Valve (DIN : Heavy duty casted brass) with nozzle for ergonomic use in work chamber for Water / Vacuum / Air / Gas (each price).
- Chemical and acid resistant modular epoxy scaffold / lattice.
- Heavy duty PP + FRP housing assembly with PP blower, in lieu of CRC/GI motor blower housing to cost extra.
- Scrubber for use above to cost extra.