- Autoclave/Sterilizers
- Autoclave Vertical
- Autoclave Vertical Deluxe
- Autoclave Vertical Fully Automatic Digital
- Autoclave Vertical Semi Automatic Digital
- Autoclave Vertical High Pressure (FAD)
- Autoclave Vertical High Pressure (SAD)
- Autoclave Horizontal (Cylindrical)
- Steam Sterilizer Horizontal High Pressure
- Steam Sterilizer Horizontal H. P. Rectangular
- Autoclave Portable
- Tabletop Autoclave
- more..
- Freezers/Refrigerators
- Blood Bank Refrigerators
- Medical/Biomedical Equipment
- Biological Safety Cabinets
- Clean Air Benches
- Seed Germinators
- Environmental/Growth Chamber
- Ovens
- Incubators
- B.O.D. Incubator
- Water Still/Distillation Plants
- Water Baths
- Refrigerated Circulating Water Bath
- Chiller Circulating Water Bath
- Ultrasonic Cleaning Bath
- Circulating Water Bath (Heated)
- Water Bath Rectangular (Single Wall)
- Water Bath Rectangular (Double Wall)
- Serological Water Bath
- High Precision Water Bath
- Water Bath Incubator Shaker (Metabolic Shaker)
- Tissue Floatation Bath
- Inspissator
- more..
- Hot Plates Warming Tables
- Dry Block Digesters
- Shaking Machines/ Stirrers
- Muffle Furnace
- General Laboratory Equipment
- Aerosol Disinfector
- Automatic Pipette Washer
- Bomb Calorimeter Digital
- Bottle Top Dispenser
- Colony Counter Digital
- De Humidifier
- Ice Flaking Machine
- Lyophilizer Freeze Dryer
- Electronic Filling Device
- Electronic Micropipettes
- Heating Mantle
- Humidifier
- Kjeldahl Digestion Unit
- Kjeldahl Distillation Digestion
- Kjeldahl Distillation Unit
- Melting Point Apparatus
- Micropipettes Fully Autoclavable
- Micropipettes Semi Autoclavable
- Multi Channel Fully Autoclavable
- Multi Channel Non Autoclavable
- Oven Universal Memmert Type
- Soxhlet Extraction Unit
- Ultra Violet Flourescent Analysis
- Vacuum Pump Oil Free
- Vacuum Pump Oil Free
- more..
- Water Testing Equipments
Steam Sterilizer High Pressure Cylindrical (MSW-104)
RELIABLE » TRUST WORTHY » EFFECIENT

APPLICATIONS
- “MAC” Horizontal Autoclave Triple Walled are most ideal for critical applications requiring assured and reliable total destruction of all living micro-organisms.
- Steam Sterilizer is an ideal tool for Laboratories, hospitals, nursing homes, R&D labs etc.
CONSTRUCTION AND FEATURES
- The inner chamber, steam jacket, outer chamber and boiler are made of heavy gauge stainless steel with leak proof argon arc welding.
- The radial locking lid is made of thick S.S. plate.
- The space between the outer chamber and steam jacket is filled with glass wool to minimize thermal losses.
- Hydraulically tested to withstand 2.5 times the working pressure.
- Steam boiler is fitted with water level indicator, pressure gauge, low water cut-off device and automatic pressure control device.
- Fitted with safety valve as a safety device.
- Drain valve is fitted at the side bottom for easy draining/cleaning.
- The unit is provided with a positive self-locking safety door which cannot be opened while the chamber is under pressure and disengages automatically when chamber is exhausted.
- This affords complete safety to the working personnel against explosive opening.
- Two seperate valves are provided for evacuating steam from inner chamber and jacket as and when desired.
- Sterilization Cycle is controlled by SINGLE POINT MULTIPORT Valve.
- The chamber discharge line is fitted with a moisture trap to absorb the condensate automatically thus preventing moistening of the loaded material to be sterilized.
- An automatic vacuum breaker is fitted to all “MAC” units as a standard accessory, in order to break vacuum in case of steam condensation.
- The flanged immersion type heating element made from very high grade material provides fast formation of pressure in the system and are protected through a electric low water level cut-off device.
- All “MAC” Sterilizers are provided with triple safety features, through a “PIEZOSTAT” (Automatic Pressure Control System) and a spring loaded safety valve fitted to the boiler/steam generator. The chamber is fitted with spring loaded safety valve and a dead weight release valve.
- Highly accurate temperature indicator is fitted for monitoring temperature.
- In addition to vacuum dry provided in the MPV an extra injector can be provided in the autoclave for better drying of the load.
- POP type safety valve can be installed in lieu of spring load safety valve, for more accurate & better performance. (OPTION)
- To work on 440Volts, 3phase, 50Hz AC supply.
Technical Specifications & Ordering Informations
Model (With Tubular Stand & Supporting Ring of M.S.)
#AHC-88
#AHC-162
#AHC-165
#AHC-221
MODEL (All S.S. Body)
#AHCSS-88
#AHCSS-162
#AHCSS-165
#AHCSS-221
Inner Dimensions (Dia x Depth)
400x600mm
400x1100mm
500x900mm
500x1200mm
Capacity
88 ltrs
162 ltrs
165 ltrs
221 ltrs
Heater Load
6.0 KW
9.0 KW
9.0 KW
9.0 KW
Gasket
Made of Jointless Silicon Rubber
Display
Dial Thermometer (Standard with the unit)
Exhaust Pressure
Manual through a Exhaust valve
Sterlizing Pressure
1.2 to 1.5 kgf/cm² (15 to 20 psi) at 121 °C
Operating Pressure
From 15 Psi 20 Psi
Pressure Gauge
0-2.1 kgf / cm² (30 Psi
MOC (Pressure Vessel)
Stainless Steel (SS-304)
MOC (Jacket)
Stainless Steel (SS-304)
MOC (External Wall)
Stainless Steel (SS-304)
MOC (Boiler)
Stainless Steel (SS-304)
MOC (Lid)
Stainless Steel (SS-304)
Power Supply
440V AC, 3 Phase Supply.
Tubular Stand & Supporting Rings
Made of Mild Steel or Stainless Steel (as ordered).
Double Door (OPTION)
Option available at extra cost
options
- Digital Temperature Indicator can be supplied in lieu of dial thermometer.
- Microprocessor Based Digital Temperature Indicator cum Controller in lieu of Dial Thermometer to cost extra.
- Microprocessor Based Digital Temperature Indicator cum Controller with LED display with set value and process value. Fitted with Automatic Digital Minute Timer which starts automatically when set/desired value of temperature is achieved. When the set time period is over heaters get switched off automatically with alarm for cycle end.
- Digital Pressure gauge with electronic transducer and syphon
- Extra injector in addition to vacuum dry can be provided at an extra cost for better drying.
- POP type safety value in lieu of spring loaded safety valve, at an extra cost.